Detail Kyoritsu 3021 Digital Insulation / Continuity Tester
Kyoritsu 3021 Digital Insulation / Continuity Tester
• Combining three functions in one unit, the Kyoritsu 3021 Digital Insulation/ Continuity Tester performs insulation test with 4 voltage ranges, continuity testing and AC voltage measurement.
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0© adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT.III 600V
Specification: Insulation resistance
* Test voltage 125V
Measuring range ( Auto range) : 4.000/ 40.00/ 200.0M©
First Effective Measuring range : 0.1~ 20M©
Mid-scale value : 5M©
Accuracy : ± 2% rdg± 6dgt
Second effective measuring range lower : 0~ 0.099M©
Second effective measuring range upper : 20.01~ 200.0M©
Accuracy : ± 5% rdg± 6dgt
Rated current : DC 1~ 1.2mA
Output short circuit current : 1.5mA max
Test voltage 250V
• Measuring range ( Auto range) : 4.000/ 40.00/ 400.0/ 2000M©
• First Effective Measuring range : 0.1~ 40M©
• Mid-scale value : 5M©
• Accuracy : ± 2% rdg± 6dgt
• Second effective measuring range lower : 0~ 0.099M©
• Second effective measuring range upper : 40.01~ 2000M©
• Accuracy : ± 5% rdg± 6dgt
• Rated current : DC 1~ 1.2mA
• Output short circuit current : 1.5mA max
Test voltage 500V
• Measuring range ( Auto range) : 4.000/ 40.00/ 400.0/ 2000M©
• First Effective Measuring range : 0.1~ 200M©
• Mid-scale value : 50M©
• Accuracy : ± 2% rdg± 6dgt
• Second effective measuring range lower : 0~ 0.099M©
• Second effective measuring range upper : 200.1~ 2000M©
• Accuracy : ± 5% rdg± 6dgt
• Rated current : DC 1~ 1.2mA
• Output short circuit current : 1.5mA max
Test voltage 1000V
• Measuring range ( Auto range) : 4.000/ 40.00/ 400.0/ 2000M©
• First Effective Measuring range : 0.1~ 1000M©
• Mid-scale value : 50M©
• Accuracy : ± 2% rdg± 6dgt
• Second effective measuring range lower : 0~ 0.099M©
• Second effective measuring range upper : 1001~ 2000M©
• Accuracy : ± 5% rdg± 6dgt
• Rated current : DC 1~ 1.2mA
• Output short circuit current : 1.5mA max
© / Continuity
• Auto range : 40.00/ 400.0©
• Accuracy : ± 2% rdg± 8dgt
• Output Voltage on open circuit : 5V± 20%
• Output short circuit current DC : 220± 20mA
• Fuse Quick acting ceramic fuse : 0.5A/ 600V ( Ø 6.35x32mm)
AC Voltage
• Range AC : 20~ 600V ( 50/ 60Hz)
• DC : -20~ -600V/ + 20~ + 600V
• Accuracy : ± 3% rdg± 6dgt
General
Applicable standards : IEC 61010-1 CAT.III 600V, IEC 61557-1, 2, 4, IEC 61326-1 ( EMC) , IEC 60529 ( IP40)
Dimensions/ Weight : 105( L) x 158( W) x 70( D) mm / 600g approx.
Power source : R6Px6 or LR6x6
Accessories : 7150A ( Remote control switch set) , 9121 ( Shoulder strap) , R6P ( AA) x6, Instruction Manual
Optional : 7115 ( Extension Probe) , 8016 ( Hook type prod) , 8923 ( Fuse [ 0.5A/ 600V] ) , 9089 ( Carrying Case)