Detail APPA 106 The Thoughest Multimeters
APPA 106 The Thoughest Multimeters
OVERLOAD PROTECTION
High energy fuses, PTCs, and fusible resistors protect APPA 100 Series multimeters, and its user, form overloads.
OPTICAL RS-232 INTERFACE
All new APPA 100 Series has RS-232 optical interface to connect to PC for data acquistion. APPA 107N and APPA 109N can be self-calibrated in connection with calibrator, also have self-data logging function without connecting to a computer.
DAY & NIGHT
All new APPA 100 Series has LED backlit display that turns ON/ OFF at the touch of a button, also automatically goes off to save battery life.
EXTRA PROTECTION
Every APPA 100 Series meter is supplied with a protective holster that includes a built-in tilt stand, a nail hook, and convenient test lead storage. This holster provides an extra degree of protection and convenience for your meter.
NO-OPTION FULL ACCESSORIES
Ergonomicly designed test leads with comfort-grip, safety-shrouded, full sleeve right-angle plug and hard alloy tips for long life. Slip-on insulated alligator clips are standard. Also supplied with temperature adaptor and bead sensor.
BATTERY EASY TO REPLACE
Unscrew only two screws to remove battery door for battery replacement, designed for user' s convenience without opening the bottom case.
Specifications
Voltage AC
• Range: 400.0mV~ 750V
• Basic Accuracy: + / -( 1.0% + 5d)
• Input Impedance: 10M? / / 100pF
• Frequency Resonse: 40Hz~ 1kHz
• Overload Protection: 1000V DC or 750V rms
Voltage DC
• Range: 400.0mV~ 1000V
• Basic Accuracy: + / -( 0.1% + 1d)
• Input Impedance: 10M?
• Overload Protection: 1000V DC or 750V rms
Current AC
• Range: 40.00mA~ 10A
• Basic Accuracy: + / -( 1.3% + 5d)
• Conversion Type: True RMS reading on AC mode
• Frequency Resonse: 40Hz~ 1kHz
• Input Protection: Equipped with High Energy Fuse, 1A, 600V, IR 10KV fuse for mA input. 15A, 600V, IR 100KV fuse for A input
Current DC
• Range: 40.00mA~ 10A
• Basic Accuracy: + / -( 0.4% + 2d)
• Input Protection: Equipped with High Energy Fuse. 1A, 600V, IR 10KV fuse for mA input 15A, 600V, IR 100KV fuse for A input
Resistance
• Range: 400.0? ~ 40.00M?
• Basic Accuracy: + / -( 0.4% + 2d)
• Overload Protection: 600V rms
Continuity Beeper : < 50? , 2k Hz tone buzzer
Diode Test
• Open circuit voltage: 3V
Capacitance
• Range: 4.000nF~ 10mF
• Basic Accuracy: + / -( 2.0% + 5d)
• Overload Protection: 600V rms
Frequency Counter
• Range: 4kHz~ 400MHz
• Basic Accuracy: + / -( 0.01% + 1d)
• Overload Protection: 600V rms
RPM
• Range: 40kRPM~ 400kRPM
• Basic Accuracy: + / -( 0.01% + 10d)
• Overload Protection: 600V rms
Temperature
• Range: -20? ~ 800?
• Basic Accuracy: + / -( 2% + 2? ) at 351? ~ 500?
• Overload Protection : 600V rms
General Specifications
Display : 4000 count, 82 segment analog bargraph
Measuring Rate : 2.5times/ sec for 4000 count and 20 times/ sec for analog bargraph
Overload Indication
Auto Power Off : " OL" or " -OL"
Operating Temperature : -20? ~ 50? , < 80% RH
Storage Temperature : -20? ~ 60?
Temperature Coefficient : 0.15( Spec. Acc) / ? , 28?
Safety : IEC61010 and designed to meet UL61010 specifications
Battery Life : 300 hours ( Alkaline)
Size
• 86mm ( W) x 185mm ( L) x 31.5mm ( H)
• 98mm ( W) x 197mm ( L) x 50mm ( H) with holster
Weight : 620 grams
Included with Instrument : Protective holster, test leads, test clips, ZnC battery( Installed) , manual, Optical RS-232 cable( 109N) , and WinDMM 100S( 109N)
Tampilkan Lebih Banyak